STUDIO DEL TRANSITORIO NELLA TRASMISSIONE DALLA P.D.P. AL VENTILATORE DI UN NEBULIZZATORE

Submitted: 26 June 2012
Accepted: 26 June 2012
Published: 31 March 2007
Abstract Views: 778
PDF: 641
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

During the use of a number of mistblowers for the orchard and vineyard protection, the overgear-box, located between the p.t.o. and the centrifugal fan, was damaged. To solve the problem we carried-out a dynamic analysis of initial no steady-state by integrating the differential equation of the impeller motion. By the obtained equations, a numerical experimentation was carried-out. It showed the gearing of a power greater than design power of the overgear box, due to impeller inertia. This result explains the overgear box damages and gave the no steady-state condition time (1,8 s), to get the rated velocity of the impeller. Finally a torque limiter assembling, between the p.t.o. and the overgear box, was proposed. A new differential equation solution and a new numerical experimentation was carried-out. It showed a reduction of the geared power to the rated value of the overgearbox, together with an increase of the no steady-state condition time to 8,7 s.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

How to Cite

Friso, D. (2007) “STUDIO DEL TRANSITORIO NELLA TRASMISSIONE DALLA P.D.P. AL VENTILATORE DI UN NEBULIZZATORE”, Journal of Agricultural Engineering, 38(1), pp. 47–52. doi: 10.4081/jae.2007.1.47.