Soil electrical conductivity estimated by time domain reflectometry and electromagnetic induction sensors: Accounting for the different sensor observation volumes

Published: 4 December 2017
Abstract Views: 1569
PDF: 806
Appendix: 554
HTML: 212
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

This paper dealt with the calibration of an EMI sensor for monitoring the time dynamics of root zone salinity under irrigation with saline water. Calibration was based on an empirical multiple regression approach largely adopted in the past and still applied in practice for its relative simplicity. Compared to the more complex inversion approaches, it requires an independent dataset of local σb measured within discrete depth intervals, to be compared to horizontal and vertical electrical conductivity (ECaH and ECaV) readings for estimating the parameters of the empirical regression equations. In this paper, we used time domain reflectometry (TDR) readings to replace direct sampling for these local σb measurements. When using this approach, there is the important issue of taking into account the effect of the different sensor observation volumes, making the readings not immediately comparable for empirical calibration. Accordingly, a classical Fourier’s filtering technique was applied to remove the high frequency part (at small spatial scale) of the original data variability, which, due to the different observation volume, was the main source of dissimilarity between the two datasets. Thus, calibration focused only on the lower frequency information, that is, the information at a spatial scale larger than the observation volume of the sensors. By this analysis, we showed and quantified the degree to which the information of the set of TDR readings came from a combination of local and larger scale heterogeneities and how they have to be manipulated for use in EMI electromagnetic induction sensor calibration.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

Crossref
Scopus
Google Scholar
Europe PMC
Ali Saeed, School of Agricultural, Forestry, Food and Environmental Sciences, University of Basilicata, Potenza
Land and Water Division

How to Cite

Saeed, A. (2017) “Soil electrical conductivity estimated by time domain reflectometry and electromagnetic induction sensors: Accounting for the different sensor observation volumes”, Journal of Agricultural Engineering, 48(4), pp. 223–234. doi: 10.4081/jae.2017.716.

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.